logo
Enviar mensaje
Hogar
Productos
Videos
Sobre nosotros
Viaje de la fábrica
Control de calidad
Éntrenos en contacto con
Solicitar una cotización
Noticias
Noticias de la compañía
BOGEN PUMPS
Inicio ProductosBomba de la transferencia del diafragma

Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

Porcelana BOGEN PUMPS certificaciones
Porcelana BOGEN PUMPS certificaciones
BA50 ES BUENO POR AHORA

—— Pozo del trabajo

Buen trabajo, gracias por darme grandes vacaciones. Un saludo Vinod

—— Vinod Bernardo

¡Cooperación agradable! Apreciamos para la ayuda buena de su compañía en nuestros proyectos. Servicio muy bueno

—— Sr. Hussain

Estoy en línea para chatear ahora

Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration
 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

Ampliación de imagen :  Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

Datos del producto:
Lugar de origen: China
Nombre de la marca: BSK
Número de modelo: BSKA25AL-P99-A
Pago y Envío Términos:
Cantidad de orden mínima: 10 unidades
Precio: negotiable
Detalles de empaquetado: Bosque
Tiempo de entrega: 5 DÍAS
Condiciones de pago: MANDO T/T
Capacidad de la fuente: 1000 unidades por mes
Garantía:: Un año
Descripción detallada del producto
Nombre del producto: bomba de diafragma neumática Materiales: Fundición de acero
Presión de aire máxima: 8.3bar el ruido: <80db>
Max. Installation Dimension: 249.5×360.5×245m m Flujo máximo: 135L/MIN
Resaltar:

food grade diaphragm pump

,

air operated submersible pump

Positive Displacement Water Pump Air Operated With Low Vibration

 

 

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

 

Product Description:

 

Air Inlet

1/4-18NPTF-1

Fluid Outlet

1-11-1/2NPTF-1,Rp1-11BSP

Fluid Inlet

1-11-1/2NPTF-1,Rp1-11BSP

Max. Flow

135L/Min

Max. Head

70M

Max. Self-priming Lift (dry)

4m

Max. Air Pressure

8.3bar

Max. Particle Diameter

3mm

Max. Installation Dimension

249.5×360.5×245mm

Weight

9.5kg

Noise

<80db

 

 

Specifications

 

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium
4. Material:Cast steel,Alu,SS,PP

 

Pneumatic Diaphragm Pump Advantages:

1. Explosion-proof, zero leak, simple operation.

2. Idling capability,Self suction, No complex control.

3. Diversity of material,no rotating parts,applicable to various erosive situations.

4. Diaphragm, ball and ball seat adopt imported materials with longer service life.

5. Modularization of main valve and air motor. No broken, easy to disassemble and repair.

 

Pay attention to the following points when operating with a pneumatic diaphragm pump:


1. Ensure that the maximum particles contained in the fluid do not exceed the maximum safety of the pump through the particle diameter standard.
2. The intake pressure should not exceed the maximum allowable pressure of the pump. Compressed air above the rated pressure may cause personal injury and property damage and damage the performance of the pump.
3. Ensure that the pumping piping system can withstand the highest output pressure achieved, and ensure the clean and normal working conditions of the driving pneumatic system.
4. Static sparks may cause explosions and personal injury and property damage. Use wires with a large cross-sectional area as needed to properly ground the grounding screws on the pump.
5. The grounding requirements are in compliance with local laws and regulations and some special requirements on site.
6. Tighten the pump and each connecting pipe joint to prevent static sparks from being generated by vibration. Use an antistatic hose.
7. Periodically check and test the reliability of the grounding system, requiring a grounding resistance of less than 100 ohms.
8. Maintain good exhaust and ventilation, away from inflammable, explosive and heat sources.

Maximum Applied Temperature Limits (diaphragm / ball / seal material)  

 

 

Acetal ···············································40°-         150°F        (4.4- 65.5°C)  

Santoprene····················································-40°- 225°F (-40°- 107.2°C)   ·····································································40°- 220°F (4.4°- 104°C)   Nitrile·······································································10°- 180°F (-12°- 82°C)   Viton······························································-40°- 350°F (-40°-176.6°C)   Hytrel·········································································-20°-150°F (-12°- 93°C)   Kynar·····································································10°-200°F (-28.9°- 65.5°C)   Polypropylene····················································32°- 175°F (0-79.4°C)

 

 

1”  Flow diagram

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 0

 

Installation dimensions:

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 1

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 2

 

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 3

 

 

 

 


 

 

Contacto
BOGEN PUMPS

Persona de Contacto: Mr. ALLSON

Teléfono: 008618122100289

Envíe su pregunta directamente a nosotros (0 / 3000)